The LAARS Pennant CP is an advanced, high-efficiency, hot water supply boiler designed specifically to work with heat pump systems. The Pennant CP delivers steady-state combustion efficiencies as high as 84% or more (85% minimum steady state combustion efficiency) and features fan-assisted sealed combustion, an innovative modular design, and an automatic anti-condensation system. Pennant CP units are available from 200,000 to 2,000,000 BTUs per hour (input).
Designed for fast installation, trouble-free long-term operation, and minimal yearly service requirements, every Pennant CP unit is fully modular, with separate, easily-accessible heat exchanger, burner tray, gas train, combustion blower, igniter, and electronic components, and a simple—yet sophisticated—digital operating control with front panel temperature display, precision fingertip temperature adjustment, and complete diagnostic indicator lights.

The Pennant CP also features an exclusive, built-in, fully automatic bypass system that prevents low temperature return water from causing condensation on the heat exchanger (which can damage or even destroy the boiler over time). To prevent condensation within the unit, cooler return water (as low as 50°F) is automatically mixed with some of the heated water produced by the boiler to raise its temperature to 120°F, effectively preventing condensation without requiring additional external by-pass piping, balancing valves, or constant adjustments.
 
Pennant CP units are available with or without a built-in pump, and, for applications that require greater heating capacites, individual units may be stacked on specially-designed racks. Multiple boiler installations also allow for boiler rotation (to extend operational life), redundancy (for backup purposes), or both.


LAARS Pennant CP Low Temperature Boiler

Click here for a LAARS Pennant Sales Brochure in Adobe Acrobat PDF Format (Adobe Acrobat Reader required). Brochure Click here for a LAARS Pennant Sales Brochure in Adobe Acrobat PDF Format (Adobe Acrobat Reader required). Submittal Data Click here for a LAARS Pennant Sales Brochure in Adobe Acrobat PDF Format (Adobe Acrobat Reader required). Operating Manual
| Performance Ratings | Water Flow RequirementsConnections | Parts |
  
Pennant Performance Ratings
Fuel energy input, heat energy output, and net IBR rating in BTUs per hour x 1000 (MBH); steady state combustion efficiency as a percentage; and firing mode in stages.
Model Input Output Net IBR Rating Efficiency Firing Modes
500 500 425 361 85% 2
750 750 638 542 85% 2
1000 999 849 722 85% 3
1250 1250 1063 903 85% 4
1500 1500 1275 1084 85% 4
1750 1750 1488 1264 85% 4
2000 1999 1699 1444 85% 4
Net IBR rating includes an allowance for normal piping and pickup load (about 15% of the boiler's rated output). Steady-state combustion efficiency represents the amount of heat actually available to the system compared to the amount of heat available in the fuel less any heat lost up the flue (stack loss).
Return to Top of Page
  
Pennant Water Flow Requirements
Minimum flow in gallons per minute (GPM) required to heat the boiler's inlet water by the indicated temperature rise (F°) and the resulting head loss (H/L) across the boiler's heat exchanger measured in feet.



Model

20°F Rise 25°F Rise 30°F Rise 35°F Rise
Flow H/L Flow H/L Flow H/L Flow H/L
500 43 1.7 34 1.1 28 0.9 24 0.7
750 64 3.3 51 2.3 43 1.7 36 1.2
1000 85 5.0 68 3.6 57 3.1 48 2.2
1200 106 8.1 85 6.1 71 4.7 61 3.4
1500 128 10.0 102 7.2 85 5.5 73 4.2
1750 N/R N/R 119 10.5 99 8.4 85 5.8
2000 N/R N/R 136 12.5 113 10.4 97 8.3
Head loss calculations apply only to LAARS OEM heat exchangers and allow thirty feet of piping (the same size as the heater outlet) and, typically, five to six fittings.
Return to Top of Page
 
Pennant Connections and Shipping Weights
Gas, water, combustion air intake and exhaust vent connections in inches; approximate shipping weight in pounds.
Model Gas Water Air Intake Vertical Vent  Horizontal Vent Weight
500 2 6 6 6 425
750 2 6 8 6 505
1000 8 10 8 615
1200 2 8 12 8 675
1500 2 8 12 8 760
1750 2 12 14 8 825
2000 2 12 14 12 955
Add 55 lbs. to the shipping weight for units with built-in pump.
Return to Top of Page
 
Central Florida Representative:
Manufacturer:
Conservation Systems, Inc.
5850 Lakehurst Drive, Suite 120
Orlando, FL 32819-8386
407.351.9121 Phone
407.352.6391 Fax
www.csiworldwide.com
Laars Heating Systems Co.
A subsidiary of Bradford White Corporation
1355 Kuehner Drive
Simi Valley, CA 93063-4478
1-800-900-9276
www.laars.com 
 
Specifications subject to change without notice.
Please read our Terms of Sale notice carefully before placing an order.
Site Copyright 2006 © Conservation Systems, Inc. Orlando, Florida USA
All other trademarks, logos and copyrights are the property of their respective owners.
Return to Top of Page