The LAARS Mini-Therm II hydronic heating boiler is compact, efficient, dependable, and designed specifically for residential heating applications. Its low mass, finned copper heat exchanger and fast-acting controls deliver needed warmth quickly and consistently when outside temperatures plummet. 

The Mini-Therm's standard features include:
 
Compact design with small footprint will fit through most narrow doorways and slip into small utility rooms.
 
JV Models:
85.4% AFUE Efficiency
Side-Wall Vent Available
 
JVi Models:
84.0% AFUE Efficiency
Slide-Out Burner Tray
Pilotless Hot Surface Ignition
Integral Induced Draft Fan
 
Both units feature built-in draft diverters and automatic vent dampers.

LAARS Mini-Therm II Residential Hydronic Boiler

JV Submittal Data
JV Instruction Manual
JVi Submittal Data
JVi Instruction Manual
| JVi Ratings | JV Ratings | Parts |
    
Mini-Therm JVi Ratings
Performance ratings, fuel utilization, connection sizes and approximate shipping weight.
Model 50 75 100 125 160 225
Input MBH 50 75 100 125 160 225
Heating Capacity for Natural Gas MBH 41.5 62.3 82.0 102.5 161.2 184.5
Heating Capacity for Propane Gas MBH 42.0 63.0 83.5 103.0 132.8 187.2
Net IBR for Natual Gas MBH 36.1 54.2 72.6 89.6 114.1 160.4
Net IBR for Propane Gas MBH 36.5 54.7 72.6 89.6 115.5 162.8
AFUE for Natural Gas % 83.4 83.2 82.4 82.4 82.3 82.2
AFUE for Propane Gas % 84.0 84.0 84.0 82.8 82.4 83.2
Water Connection in.
Gas Connection in. ½ ½ ½ ½ ½ ½
Approximate Weight lbs. 160 165 180 185 210 225
Return to Top of Page
 
Mini-Therm JV Ratings
Performance ratings, fuel utilization, connection sizes and approximate shipping weight.
Model 50 75 100 125 160 225
Input MBH 50 75 100 125 160 225
Heating Capacity for Natural Gas MBH 42 63 83 104 133 186
Heating Capacity for Propane Gas MBH 43 64 85 106 135 190
Net IBR for Natual Gas MBH 36.5 54.8 72.2 90.4 115.7 161.7
Net IBR for Propane Gas MBH 37.4 55.6 73.9 92.2 117.4 165.2
AFUE for Spark Ignition Natural Gas % 84.4 84.0 84.0 83.0 83.0 83.2
AFUE for Standing Pilot Propane Gas % 85.4 85.2 85.0 84.5 84.8 85.0
AFUE for Spark Ignition Propane Gas % 80.2 80.5 80.7 80.7 81.0 81.5
AFUE for Standing Pilot Propane Gas % 82.0 82.5 82.7 82.7 83.0 83.5
Water Connection in.
Gas Connection in. ½ ½ ½ ½ ½ ½
Approximate Weight lbs. 120 126 134 138 164 181
Return to Top of Page
 
Central Florida Representative:
Manufacturer:
Conservation Systems, Inc.
5850 Lakehurst Drive, Suite 120
Orlando, FL 32819-8386
407.351.9121 Phone
407.352.6391 Fax
www.csiworldwide.com
Laars Heating Systems Co.
A subsidiary of Bradford White Corporation
1355 Kuehner Drive
Simi Valley, CA 93063-4478
1-800-900-9276
www.laars.com 
 
Specifications subject to change without notice.
Please read our Terms of Sale notice carefully before placing an order.
Site Copyright 2006 © Conservation Systems, Inc. Orlando, Florida USA
All other trademarks, logos and copyrights are the property of their respective owners.
Return to Top of Page